5000L Ro plant detail configuration as below :
(we can do 0.5T to 500T per hour RO system , the project also can make to order , can choose other brand pump and membrane , like Grundfos pum , Dow membrane , Toray Membrane and so on )
No. | Item | Origin/brand | Quantity | |
1 | Raw water tank is 5.0 m3 | Customer supply | 1pc | |
A. Material: PE anticorrosion | ||||
B, specification: 1800×2300mm | ||||
C. Water level control switch | 1pc | |||
2 | Raw water pump (CHL8-40) 304 stainless steel | CNP | 2pcs | |
A. Flow rate: 8.0m3/ H Head: 35m K= 1.5KW | ||||
B, including: water inlet valve, check valve pipe, etc | 1set | |||
3 | Quartz sand filter 900×2150mm | CHUNKE | 1pc | |
A. Material of tank: SS304 | CHUNKE | 1pc | ||
B.Auto Valve F75A | RUNXIN | 1pc | ||
C. Upper and lower water distributor | 1set | |||
D. Clean water quartz sand | CHINA | 1300kg | ||
4 | Active carbon filter 900×2150mm | CHUNKE | 1pc | |
A. Material of tank: SS304 | CHUNKE | 1PC | ||
B.Auto Valve F75A | RUNXIN | 1PC | ||
C. Upper and lower water distributor | 1SET | |||
D. Activated carbon filter material | High quality coconut shell | 350KG | ||
5 | Dosing system (scale inhibitor) | SEKO | 1套 | |
A. Flow rate 1.0L/H Head: 70M | ||||
B. Dosing barrel 40L (PE) | 1个 | |||
C. Debugging potions | 25KG | |||
6 | Dosing system (reducing agent) | SEKO | 1set | |
A. Flow rate 1.0L/H Head: 70M | ||||
B. Dosing barrel 40L (PE) | 1pc | |||
C. Debugging potions | 25KG | |||
7 | 5um security filter 40 inch 7 core | CHUNKE | 1set | |
A. Shell material: 304 stainless steel | CHUNKE | 1pc | ||
B. Overall size: 230×1000MM | ||||
C, 40 "×5 m PP filter element | GUANGZHOU | 7pcs | ||
8 | HP Pump(CDLS8-14) SS304 | CNP | 1pc | |
A. Flow rate 10m3/h Head: 115m K= 5.5kW | ||||
B, including: water inlet valve, check valve pipe, etc | 1 batch | |||
9 | One stage reverse osmosis pure water unit yield: 5.0m3/h, desalination rate: 96-99%, system water utilization rate: 55-65% | 1set | ||
Include | A. Membrane shell 8040-3, 8040-2 | CHUNKE | 2pcs | |
Material: FRP | VONTRON | 5pcs | ||
B. Membrane element RO-8040 | CHUNKE | 1pc | ||
C. 304 Stainless steel frame | Brass material | 1pc | ||
D. Inlet electromagnetic valve DN50 | Brass material | 1pc | ||
E. Concentrated water solenoid valve DN32 | SS 304 | 1pc | ||
F. Inlet water regulating valve DN40 | SS 304 | 1pc | ||
G. Concentrated water flow control valve DN32 | UPVCmaterial | 1pc | ||
10 | Pressure gauge | China | 1 batch | |
A. Reverse osmosis pressure gauge 0 ~ 25kGF /cm2 | China | 2pcs | ||
B. Pretreatment pressure gauge 0 ~ 7kgf/cm2 | CHINA | 4pcs | ||
C. High voltage protection switch (P-06) | CHINA | 1pc | ||
D. Low-voltage protection switch (P-06) | CHINA | 1pc | ||
E. Inlet conductivity meter | CHINA | 1pc | ||
F. Water-producing conductance instrument | CHINA | 1pc | ||
11 | Flow meter 0-10t /H | CHINA | ||
A. Water production flowmeter | 1pc | |||
B. Concentrated water flowmeter | 1pc | |||
C. Backwater flowmeter | 1pc | |||
12 | Pure water tank (capacity: 5.0m3) | Customer supply | 1pc | |
A. Material :PE anticorrosion | ||||
B, specification: 1800×2300mm | ||||
C. Water level control switch | 1pc | |||
13 | Cleaning system (7.0m3/h) | 1pc | ||
① Cleaning pump (CHM4-4, stainless steel) | CNP | 1pc | ||
Flow: 7.0m3/ H Head: 19m | ||||
Power: 0.75 kw | ||||
Include: return valve, pipe, etc | 1 batch | |||
| CHUNKE | 1 pc | ||
Material: PE anticorrosion | ||||
Including: inlet and outlet water pipeline 1 batch | ||||
| CHUNKE | 1set | ||
Model: 40 "×5 Core village quality: stainless steel | CHUNKE | 1pc | ||
"40 x 5 microns PP filter | 5pcs | |||
14 | Connect pipe fitting and valve | TAIWAN | 1set | |
A. Valves and pipes (SS304) DN15-DN50 | TAIWAN | 1 batch | ||
B. Valves and pipes (304 stainless steel) dn15-DN40 | CHINA | 1 batch | ||
15 | Electric control system | CHUNKE | 1 set | |
Automatic CONTROL of PC program controller, Schneider electric, RO film automatic flushing, water level control of original and pure water tanks automatically stop and start up, functions of low pressure, high pressure, overheat, overcurrent, overload protection and alarm, manual operation is reserved. | ||||
A. Air switch | Schneider | 2pcs | ||
B. Ac contactor | Schneider | 1 batch | ||
C. Thermal overload protector | Schneider | 1 batch | ||
D. Insurance management | Schneider | 1 batch | ||
E. Indicator light | Schneider | 1 batch | ||
F. Third-gear switch; | Schneider | 1 batch | ||
Scram button | 中 国 | 1set | ||
G. PC automatic program controller | 中 国 | 1 batch |
RO System Includes:
Feed Water Pump
Pretreatment Filter (according to your water anlysis report choose the Multi-media filter,Activated carbon filter,soften system )
PH Dosing system
Cartridge filter
CIP Clean System
High pressue pump
RO Membrane
Main Technical Parameters:
Model | Flow rate (L/h) | Power(KW) | Water use efficiency | RO membrane | Dimension L X W X H(mm) |
RO-500L | 500 | 1.5 | ≥ 50% | 4040 | 1650X630X1800 |
RO-750L | 750 | 2.5 | ≥ 50% | 4040 | 1870X630X1850 |
RO-1000L | 1000 | 2.5 | ≥ 50% | 4040 | 1870X650X1850 |
RO-2000L | 2000 | 3.5 | ≥ 50% | 4040 | 2440X650X1750 |
RO-3000L | 3000 | 4 | ≥ 50% | 4040 | 2440X620X1850 |
RO-5000L | 5000 | 7.5 | ≥ 50% | 8040 | 2000X900X1800 |
RO-6000L | 6000 | 9.5 | ≥ 60% | 8040 | 3000X900X1800 |
RO-8000L | 8000 | 13.5 | ≥ 60% | 8040 | 3000×900×1800 |
RO-9000L | 9000 | 14 | ≥ 60% | 8040 | 4000X900X1800 |
RO-10T | 10T/H | 19 | ≥ 60% | 8040 | 3000X900X1800 |
RO-12T | 12T/H | 19.5 | ≥ 60% | 8040 | 4000X900X1800 |
RO-15T | 15T/H | 23 | ≥ 60% | 8040 | 4000X900X1950 |
RO-20T | 20T/H | 28 | ≥ 60% | 8040 | 5000X900X1950 |
RO-30T | 30T/H | 55 | ≥ 60% | 8040 | 7000X900X1950 |
Flow Chart Of RO Water Treatment Machine
Raw water pump - Sand filter - Carbon filter -Cartridge filter - High pressure pump- RO membrane host-RO Cleaning system
1. Raw water supply pump: To use CNP
Reverse Osmosis Modules( RO)
RO system is key part for the water treatment system, which is widely used to make the pure water and drinking water. RO membrane removes many types of large molecules and ions from solutions by applying pressure to the solution when it is on one side of a selective membrane. The result is that the solute such as iron, Virus, bacteria and solids is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side.
Piping, Valves & Fittings
The pipe, valves and fittings (including tubing) ball valves, butterfly valves, piping used to the system is SS304. Reverse Osmosis Modules is equipped with sample valve for the convenience to check the product water.
Control devices
The whole automatic production line is achieved through the converter and PLC programmer and data collector such as the liquid lever sensor, flow sensor and etc. The whole production line is monitored by remote computer. When the water level of the product water tank is high, the system will stop automatically. When the water level of the product water tank is low, the system will run automatically.
Advantages of RO systems:
Running stablely, high desalination and recovery rate.
Easy to operate and small maintenance workload
Compact structure and saves installation place.
Highly efficient and low energy consumption
No secondary pollution and low operation cost
Applications for RO plants:
• Homes and villas
• Hotels/hospitals
• Commercial complexes
• Kindney dialysis Unit
• Poultry farms
• Food and beverages industry
• Bottled water plants
• Cooling tower /boiler feed water
Why Choose us?
We have professional QC team to check the equipment' s quality before delivery. And we could provide the free technical training anytime.
1. Provide complete OEM or ODM water treatment solution based on your source water.
2. Our Engineer has over 20 years experience on water treatment plant
3. We have the professional QC team to check the quality before delivery.
4. The durable High-impact carton to protect the products.The packaging is sturdy, so that there is no problem in transportation.
5. Reply in 12 hours.
6. Lead time for water filter cartridge is 5-7 working days.Lead time for the water treatment system is 7-15 working days
5000L RO plant Detail Pictures :
Chunke company introduction
Welcome to contact to us for quotation !