Add to Cart
RO Controller Seawater Desalination System Complete Deionized Water Plant
Model Number | Capcity(L/H) | Power(K/W) | RO Membrane | Size L*W*H(MM) |
CK-RO-250 | 250 | 2.0 | 4040-1 | 1900*700*1400 |
CK-RO-500 | 500 | 2.0 | 4040-2 | 2250*700*1500 |
CK-RO-1000 | 1000 | 2.5 | 4040-4 | 2600*700*1500 |
CK-RO-2000 | 2000 | 3.5 | 4040-8 | 4000*800*1650 |
CK-RO-3000 | 3000 | 4.5 | 4040-12 | 4000*900*1750 |
CK-RO-4000 | 4000 | 6.5 | 8040-4 | 4750*900*1750 |
CK-RO-5000 | 5000 | 8.0 | 8040-5 | 4850*900*1900 |
CK-RO-6000 | 6000 | 8.0 | 8040-6 | 5500*800*1900 |
CK-RO-10000 | 10000 | 18.0 | 8040-10 | 5500*900*2850 |
1) Main design basis
Raw water source: municipal tap water
Water quality: see the water quality analysis report:
2) System production requirements:
(1) the water quality of the pure water machine reached the national standard for drinking water
System water: 1) guarantee the water yield of reverse osmosis pure water machine: > 1000L/H
2) ensure full automatic production
3) ensure that the equipment is capable of working for 24 hours continuously.
(2) utilization rate of new system water:
1) recovery rate of reverse osmosis equipment: > 50%
2) reverse osmosis device desalination rate: > 99%
(3) total system power: 5Kw
(4) power supply: 3 phase 4 line 380V 50Hz
(6) design: water temperature 15 ℃
4. The requirements of the system to the outside world:
1) water supply: according to the capacity proposed by us, the original amount of water: > 5m3 / h
2) power supply: according to our proposed capacity, power supply will be sent to our power cabinet.
Brackish Water Treatment Plant Detail Picture