Ask Latest Price
Video Channel
Brand Name :CHUNKE
Model Number :CK-RO-2300L/H(B2)
Certification :CE,ISO
Place of Origin :China
MOQ :1 unit
Price :Negotiable
Payment Terms :TT
Supply Ability :30 Sets Per Months
Delivery Time :22 working days
Packaging Details :wooden box package
Application :pure water
Control :automatic
Membrane :Reverse osmosis 4040
Function :remove heavy metal
Capacity :2300L Per Hour
Material :FRP+SS304
Heat removal rate :≥99.9%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Industry Reverse Osmosis for Hotel Drinking Water Purification with manual sand carbon softener with mix bed

Detail of 2300L RO System

Items Commodity Origin/brand
1 Raw water tank 2.0m3 User-supplied
2 Dosing system (coagulant) SEKO
3 Raw water pump (CM5-4) SS304 Grundfos
4 Quartz sand filter φ500×1850mm Chunke
5 Activated carbon filter φ500×1850mm Chunke
6 Water softeren φ500×1850mm Chunke
7 Dosing system (scale inhibitor) SEKO
8 5um security filter 20 inch 5 core Chunke
9 High pressure pump (CRI5-18) Grundfos
10 First-stage reverse osmosis pure water device Water production: 2.3m3/h, salt rejection rate: 96~99%, system water utilization rate: 50-60%
Inlcude A, membrane shell 8040-1 Material: FRP Chunke
B, membrane element BW30-400 Filmtec
11 Cleaning system (7.0m3/h)
① 1, cleaning pump (CM5-4) Grundfos
  • 2, cleaning the water tank (300L)
Chunke
  • 3, cleaning the filter
Chunke
12 Pure water tank (capacity: 3.0m3) User-supplied
13 Pure water pump CRIS3-12 Grundfos
14

Fine mixed bed filter φ300×1320mm

(Resin user-supply)

Wave
15 0.45um precision filter 20 inch 5 core Chunke
16 UV sterilizer 304 stainless steel Chunke
17 0.22um precision filter 20 inch 5 core Chunke
18 Pressure gauge China
19 Flow meter 0-20GPM China
20 Connecting pipe fittings, valves China
21 Electronic control system Chunke
Siemens Germany PLC programmable controller automatic control, France Schneider Electric components, RO membrane automatic flushing, the original water tank and pure water tank water level control automatically stop, low voltage, high voltage, overheating, overcurrent, overload protection and alarm function, reserved Manual operation function.

Why we use mix bed with reverse osmosis system?

Mixed bed means a system in which water is passed through a hydrogen-containing cation exchange resin and a hydroxide-containing anion exchange resin. A hydrogen type cation exchange resin is used to remove cations in water; a hydroxide type anion exchange resin is used to remove anions in water. The mineral salts in the water are substantially removed by a mixed bed. In order to obtain a better desalination effect, the mixed bed is loaded with a strong acid cation exchange resin and a strong base anion exchange resin. Mixed beds are also divided into in-vivo synchronous regenerative mixed beds and in vitro regenerative mixed beds.

Equipment for the mixed bed processing process includes a hybrid ion exchanger and an in vitro regeneration device. Among them, the in vitro regeneration equipment mainly includes a resin separator, a cathode (yang) resin regenerator, a resin storage tower, a hybrid resin tower, and an acid-base regeneration equipment.

Equipment advantages
1. The effluent water quality is excellent, and the effluent pH value is close to neutral.
2, the effluent water quality is stable, short-term operating conditions (such as influent water quality or composition, operating flow rate, etc.) have little effect on the quality of mixed bed effluent.
3. The impact of intermittent operation on the quality of the effluent water is small, and the time required to restore the water quality before the shutdown is relatively short.
4, the recovery rate reaches 100%

The Instructions For Use:

1.1 mainframe dimensions: 300*80*175CM, total weight: 1500Kg;

1.2 Water production: 2300L/H, conductivity of influent water ≤500us/cm, conductivity of water production ≤15us/cm;

1.3 Raw water quality: filtering ground water and tap water;

1.4 Power supply: three-phase five-wire 220V/380V/50HZ, rated total power: 6.0kw, normal operating power: 6.0kw;

1.5 Installation conditions: indoor installation; ambient temperature: 5-45 ° C;

Picture of 2300L Reverse Osmosis System:

Industry Reverse Osmosis For Hotel Drinking Water Purification With Sand Carbon Softener

Back Picture of 2300L Reverse Osmosis System:

Industry Reverse Osmosis For Hotel Drinking Water Purification With Sand Carbon Softener

Picture of 2300L Reverse Osmosis System:

Industry Reverse Osmosis For Hotel Drinking Water Purification With Sand Carbon Softener

Inquiry Cart 0